Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 740
Filter
1.
Arq. bras. oftalmol ; 87(5): e2022, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1527847

ABSTRACT

ABSTRACT Purpose: To explore the therapeutic effects of orthokeratology lens combined with 0.01% atropine eye drops on juvenile myopia. Methods: A total of 340 patients with juvenile myopia (340 eyes) treated from 2018 to December 2020 were divided into the control group (170 cases with 170 eyes, orthokeratology lens) and observation group (170 cases with 170 eyes, orthokeratology lens combined with 0.01% atropine eye drops). The best-corrected distance visual acuity, best-corrected near visual acuity, diopter, axial length, amplitude of accommodation, bright pupil diameter, dark pupil diameter, tear-film lipid layer thickness, and tear break-up time were measured before treatment and after 1 year of treatment. The incidence of adverse reactions was observed. Results: Compared with the values before treatment, the spherical equivalent degree was significantly improved by 0.22 (0.06, 0.55) D and 0.40 (0.15, 0.72) D in the observation and control groups after the treatment, respectively (p<0.01). After the treatment, the axial length was significantly increased by (0.15 ± 0.12) mm and (0.24 ± 0.11) mm in the observation and control groups, respectively, (p<0.01). After the treatment, the amplitude of accommodation significantly declined in the observation group and was lower than that in the control group, whereas both bright and dark pupil diameters significantly increase and were larger than those in the control group (p<0.01). After the treatment, the tear-film lipid layer thickness and tear break-up time significantly declined in the two groups (p<0.01). Conclusions: Orthokeratology lens combined with 0.01% atropine eye drops can synergistically enhance the control effect on juvenile myopia with high safety.


RESUMO Objetivo: Explorar os efeitos terapêuticos das lentes de ortoceratologia combinados com colírio atropina 0,01% em miopia juvenil. Métodos: Um total de 340 pacientes com miopia juvenil (340 olhos) tratados entre 2018 e Dezembro de 2020 foram divididos em Grupo Controle (170 casos com 170 olhos, lentes de ortoceratologia) e Grupo Observação (170 casos com 170 olhos, lentes de ortoceratologia combinadas com colírio atropina 0,01%). A acuidade visual melhor corrigida para longe, acuidade visual melhor corrigida para perto, dioptria, comprimento axial, amplitude de acomodação, diâmetro da pupila brilhante, diâmetro da pupila escura, espessura da camada lipídica da película lacrimal e tempo de ruptura do rasgo foram medidos antes do tratamento e 1 ano depois. A incidência de reações adversas foi observada. Resultados: Antes do tratamento, o grau esférico equivalente foi significativamente melhorado em 0,22 (0,06, 0,55) D e 0,40 (0,15, 0,72) D respectivamente no Grupo Observação e no Grupo Controle após o tratamento (p<0,01). Após tratamento, o comprimento axial foi significativamente aumentado em (0,15 ± 0,12) mm e (0,24 ± 0,11) mm respectivamente nos Grupos Observação e controle (p<0,01), enquanto, no grupo de observação, a amplitude de acomodação diminuiu significativamente e foi inferior a do Grupo Controle, e o diâmetro da pupila brilhante e o diâmetro da pupila escura aumentaram significativamente e foram maiores do que os do Grupo Controle (p<0,01). A espessura da camada lipídica da película lacrimal e o tempo de ruptura do rasgo diminuíram significativamente nos dois grupos (p<0,01) após o tratamento. Conclusões: As lentes de ortoceratologia combinadas com colírio atropina 0,01% podem melhorar significativamente o efeito controle em miopia juvenil com elevada segurança.

2.
International Eye Science ; (12): 153-157, 2024.
Article in Chinese | WPRIM | ID: wpr-1003526

ABSTRACT

AIM: To explore the accuracy of the ratio of axial length(AL)to the average corneal radius(CR)(AL/CR value, i.e., axial ratio)in assessing myopia in children and adolescents.METHOD:Cross-sectional study. A total of 340 cases(680 eyes)of children and adolescents aged 4-16 years old were collected from the ophthalmology clinic of Shangyu People's Hospital of Shaoxing between January 2022 and October 2022. All patients were subjected to optometry after cycloplegia to obtain spherical equivalent(SE), check and record the patient's AL, average CR, and calculate the AL/CR value.RESULTS:All subjects in this study underwent optometry after cycloplegia, and a total of 609 eyes(89.6%)were found to have myopia(SE≤-0.50 D), 58 eyes(8.5%)with hyperopia(SE≥+0.50 D)and 13 eyes(1.9%)with emmetropia(-0.50 D&#x0026;#x003E;SE&#x0026;#x003E;+0.50 D). There was a statistically significant difference in SE, AL and AL/CR values among different refractive states(P&#x0026;#x003C;0.01), but there was no difference in CR(P&#x0026;#x003E;0.05). All subjects have refractive parameters: SE +8.75--8.75(average -2.25±2.38)D; AL 19.91-27.54(average 24.41±1.22)mm; CR 7.17-8.71(average 7.83±0.27); AL/CR values range from 2.50-3.50(average 3.12±0.14), correlation analysis showed a relative strong negative correlation between SE and AL/CR and AL(r=-0.891, P&#x0026;#x003C;0.01; r=-0.758, P&#x0026;#x003C;0.01), but no significant correlation between SE and CR(r=0.067, P&#x0026;#x003E;0.05), there was a positive correlation between AL and CR(r=0.483, P&#x0026;#x003C;0.01). The linear relationships between SE and AL/CR, AL were SE=45.026-15.162×AL/CR, R2=0.794, SE=33.741-1.474×AL, R2=0.574, respectively. The gold standard was based on the optometric results of cycloplegia, the sensitivity, specificity, misdiagnosis rate and missed diagnosis rate of AL/CR value for myopia were 0.962, 0.839, 0.169, 0.038, respectively, and the accuracy was 94.85%, the Kappa coefficient was 0.742, and the area under the ROC curve was 0.972.CONCLUSION:With high qualitative diagnostic value for myopia and a certain clinical significance for myopia monitoring, AL/CR value can be used to guide myopia prevention and control and other related ophthalmic clinical work.

3.
International Eye Science ; (12): 127-130, 2024.
Article in Chinese | WPRIM | ID: wpr-1003520

ABSTRACT

AIM:To explore the effect of high aspherical lenticule on controlling low myopia.METHODS: Prospective study. A total of 100 patients aged 7 to 12 years old with low myopia who visited our hospital from May 1 to 31, 2022 were collected. They were divided into two groups with 50 cases in each group according to the wishes of patients. The control group was given single vision glasses after optometry, while the study group was given high aspherical lenticule. The myopia progression(absolute value), axial length(AL)growth, transition rate to moderate myopia, and AL negative growth rate over 6 mo and 1 a were compared between the two groups.RESULTS: The myopia progression and the AL growth of study group was lower than that of the control group after 6 mo and 1 a(all P&#x0026;#x003C;0.001).The negative growth rate of AL after 6 mo of treatment was significantly higher than that of the control group(P&#x0026;#x003C;0.001). The transition rate to moderate myopia between the two groups was not statistically significant(P=0.62); while the transition rate to moderate myopia in the study group was significantly lower than that in the control group after wearing lens for 1 a(P&#x0026;#x003C;0.001), and there was no statistically significant difference in AL negative growth rate between the two groups(P=0.12). Compare with single vision glasses, high aspherical lenticule achieved an 88.2% control rate for low myopia progression over 6mo and a 90.0% control rate of AL growth. The control rate for low myopia to moderate myopia was 66.7%; while the control rate of myopia progression growth was 75.6% after wearing lens for 1a, the control rate of AL growth was 69.2%, and the control rate of the transition rate to moderate myopia was 88.9%.CONCLUSION: For children and adolescents aged 7 to 12 with low myopia, high aspherical lenticule was more effective than single vision glasses in controlling myopia, making it one of the optimal choices for myopia control.

4.
International Eye Science ; (12): 97-100, 2024.
Article in Chinese | WPRIM | ID: wpr-1003514

ABSTRACT

Corneal visualization Scheimpflug technology(Corvis ST)is currently the most commonly used clinical device for assessing in vivo corneal biomechanics. The new parameter stress-strain index(SSI)has been a hot topic of clinical research in recent years, which not only directly reflect corneal biomaterial stiffness, but also closely correlates with the progression of certain diseases. SSI was generated based on the predictions of corneal behavior using finite element(FE)numerical modeling to simulate the effects of intraocular pressure and Corvis ST jets. The SSI algorithm does not change with central corneal thickness(CCT), intraocular pressure, or biomechanically corrected intraocular pressure(BIOP), but it is clearly associated with altered collagen fibres in the corneosclera. The principles of SSI, the relationship between age and SSI, the relationship between axial length and SSI, the relationship between myopia and SSI, and the application of SSI are summarized and concluded.

5.
International Eye Science ; (12): 88-92, 2024.
Article in Chinese | WPRIM | ID: wpr-1003512

ABSTRACT

As a highly prevalent global condition, myopia significantly impacts the ocular health of young individuals in China. Orthokeratology lens, as a rigid corneal contact lens, has demonstrated effective control over the progression of myopia; however, its mechanism of action remains incompletely elucidated. As one of the factors influencing visual acuity, higher-order aberrations will undergo marked changes after orthokeratology, with particular emphasis on the alterations in spherical aberrations and coma. The changes in corneal morphology induced by orthokeratology lead to significant positive increase in both spherical aberration and coma. Furthermore, the elevation of spherical aberration and coma demonstrates a negative correlation with the rate of axial length growth following orthokeratology. The interplay among spherical aberration, coma, defocus, accommodation, astigmatism, and pseudo-accommodation may constitute the underlying mechanism governing the control of myopia through orthokeratology.

6.
Rev. cuba. med ; 62(4)dic. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1550894

ABSTRACT

Introducción: El neumoencéfalo (sinonimia: aerocele o neumatocele intracerebral), se define como la presencia de gas dentro de cualquiera de los compartimentos intracraneales (intraventricular, intraparenquimatosa, subaracnoidea, subdural y epidural). Objetivo: Describir los hallazgos clínicos, estudios complementarios, conducta terapéutica y evolución de un caso con neumoencéfalo como complicación de bloqueo regional epidural por radiculopatía lumbosacra. Presentación de caso: Se presentó un paciente masculino de 57 años de edad que comenzó con un cuadro súbito de desorientación, excitabilidad psicomotriz y convulsiones tónico-clónicas, a partir de una inyección epidural de metilprednisolona como método analgésico. Conclusiones: El caso presentado exhibió manifestaciones neurológicas inespecíficas, la aparición súbita posterior al proceder invasivo hizo sospechar en un evento neurológico agudo o fenómeno tromboembólico. Los estudios complementarios como la tomografía axial computarizada craneal simple, permitió su diagnóstico para tener una conducta consecuente. El manejo conservador del neumoencéfalo como complicación del uso de anestesia epidural, constituyó una conducta terapéutica eficaz y repercutió en la satisfactoria evolución del paciente.


Introduction: Pneumocephalus (synonym: aerocele or intracerebral pneumatocele), is defined as the presence of gas within any of the intracranial compartments (intraventricular, intraparenchymal, subarachnoid, subdural and epidural). Objective: To describe the clinical findings, complementary studies, therapeutic conduct and evolution of a case with pneumocephalus as a complication of regional epidural block due to lumbosacral radiculopathy Case presentation: A 57-year-old male patient was presented who began with a sudden episode of disorientation, psychomotor excitability and tonic-clonic seizures, following an epidural injection of methylprednisolone as an analgesic method. Conclusions: The case presented exhibited non-specific neurological manifestations, the sudden appearance after the invasive procedure raised suspicion of an acute neurological event or thromboembolic phenomenon. Complementary studies such as simple cranial computed axial tomography, allowed its diagnosis to have a consistent conduct. The conservative management of pneumocephalus as a complication of the use of epidural anesthesia constituted an effective therapeutic approach and had an impact on the patient's satisfactory evolution.

7.
Rev. cuba. oftalmol ; 36(3)sept. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1550942

ABSTRACT

Objetivo: Determinar las modificaciones biométricas en pacientes miopes con implante de la lente fáquica ACRIOL 128. Métodos: Se realizó un estudio transversal con 31 ojos (17 pacientes) con alta miopía tratados con implante de lente fáquica ACRIOL 128, entre septiembre 2016 y febrero 2019, los cuales tenían mediciones biométricas preoperatorias con el sistema IOL Master 3.0.2 y estabilidad refractiva posoperatoria (≤ 0,5 dioptrías) después de los tres meses del implante. Se les efectuaron las mediciones posoperatorias con el propio IOL Master 3.0.2 en modo lente fáquica y con el sistema Scheimpflug Pentacam AXL para compararlas, mediante la prueba t para datos pareados, con una significación del 95 %. Resultados: La edad promedio fue de 29,82 ± 5,99 años, el 82,4 % del sexo femenino. El equivalente esférico preoperatorio medio fue de -12,00 ± 4,10 dioptrías. La diferencia de longitud axial y profundidad de la cámara anterior en milímetros entre el pre- y posoperatorio fue significativa con IOL Master 3.0.2 (0,13 ± 0,33 y -0,08 ± 0,17) y Pentacam AXL (0,12 ± 0,32 y -0,10 ± 0,24), respectivamente. Sin embargo, las posoperatorias entre ambos equipos no fueron significativas (p>0,05) para estas variables, pero sí para las queratometrías. Conclusiones: El implante de la lente fáquica ACRIOL 128 modifica la medición de la longitud axial y la profundidad de la cámara anterior. El IOL Master 3.0.2 y el Pentacam AXL ofrecen mediciones de longitud axial y profundidad de cámara anterior posoperatorias similares, no así para las queratometrías.


Objective: To determine the biometric modifications in myopic patients with ACRIOL 128 phakic lens implantation. Methods: A cross-sectional study was performed on 31 eyes (17 patients) with high myopia treated with ACRIOL 128 phakic lens implant, between September 2016 and February 2019, which had preoperative biometric measurements with the IOL Master 3.0.2 system and postoperative refractive stability (≤ 0.5 diopters) after three months of implantation. Postoperative measurements were performed with the IOL Master 3.0.2 in phakic lens mode and with the Scheimpflug Pentacam AXL system for comparison, using the t-test for paired data, with 95% significance. Results: The average age was 29.82 ± 5.99 years, 82.4% female. The mean preoperative spherical equivalent was -12.00 ± 4.10 diopters. The difference in axial length and anterior chamber depth in millimeters between pre- and postoperative was significant with IOL Master 3.0.2 (0.13 ± 0,33 and -0.08 ± 0.17) and Pentacam AXL (0.12 ± 0.32 and -0.10 ± 0.24), respectively. However, postoperative between the two teams were not significant (p > 0.05) for these variables but significant for keratometries. Conclusions: Implantation of the ACRIOL 128 phakic lens modifies the measurement of axial length and anterior chamber depth. The IOL Master 3.0.2 and Pentacam AXL provide similar postoperative axial length and anterior chamber depth measurements, but not for keratometries.

8.
Indian J Ophthalmol ; 2023 Aug; 71(8): 2962-2966
Article | IMSEAR | ID: sea-225201

ABSTRACT

Purpose: To compare the axial length (AL) and corneal diameter between glaucomatous eye (GE) and fellow normal eye (NE) in patients with unilateral congenital glaucoma and to obtain a normative database for ocular growth among Indian children below 3 years of age. Methods: Retrospective longitudinal study. Patients who had a follow?up of 3 years from diagnosis with ocular biometry parameters being recorded at least thrice (once a year) and fellow eye being normal were included. Data collected were age, gender, intraocular pressure (IOP), AL, corneal diameter, optic disc findings, diagnosis, and surgery details. Results: Eleven patients were analyzed. All GE underwent combined trabeculotomy with trabeculectomy. Mean (SD) baseline IOP, AL, and corneal diameter were 17.1 (6.7) mmHg, 18.9 (1.1) mm and 12 (0.91) mm in GE, and 11.1 (3.8) mmHg, 17.8 (0.44) mm, and 10.5 (0.58) mm in NE, respectively. Increase in AL was 3.1 mm in the first year followed by 0.6 mm in second year and 0.4 mm in third year in GE compared to 2.6, 0.6, and 0.5 mm in NE, respectively. Corneal diameter increased by 1.1 mm in GE in the first year and remained stable thereafter compared to 0.7 mm in first year followed by 0.3 mm in second year and stable thereafter in NE. The percentage of success was 73% at 3 years. Conclusion: Axial length and corneal diameter were higher in GE than NE at all?time points. With prompt intervention, the growth curve of the GE was made parallel to that of NE.

9.
Rev. medica electron ; 45(4)ago. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1515362

ABSTRACT

Introducción: En los últimos años se han producido cambios profundos en el manejo del paciente politraumatizado. A la vez, se han desarrollado nuevos conceptos en relación con las posibles complicaciones, los esquemas de tratamiento y las escalas pronósticas, así como en la identificación de elementos relacionados con su evolución para determinar, de manera precoz, las lesiones que amenazan la vida y precisan de un control quirúrgico inmediato o de intervencionismo radiológico. La tomografía computarizada multicorte y otros estudios imagenológicos permiten la obtención de imágenes de las estructuras corporales por planos, y proporcionan información muy detallada y útil para el diagnóstico; sin embargo, no existe consenso a la hora de indicar uno u otro en el trauma. Objetivo: Elaborar un algoritmo para la indicación eficiente de los estudios imagenológicos en el paciente politraumatizado. Materiales y métodos: Se ejecutó una investigación de desarrollo tecnológico, donde el universo de trabajo estuvo conformado por 43 pacientes con criterio de politrauma -que necesitaron estudios imagenológicos-, ingresados en el Hospital Universitario Clínico Quirúrgico Comandante Faustino Pérez Hernández, en el período comprendido entre marzo de 2020 y marzo de 2021. Resultados: Se elaboró un algoritmo para estandarizar la indicación de estudios imagenológicos en el trauma. Este trabajo considera la seguridad y protección del paciente, y el cuidado de la vida útil del equipo de tomografía axial computarizada. Conclusión: El algoritmo diseñado viabiliza la toma de decisiones respecto al uso de recursos imagenológicos en la atención a los pacientes politraumatizados.


Introduction: In recent years there have been profound changes in the management of poly-traumatized patients. At the same time, new concepts have been developed in relation to possible complications, treatment schemes and prognostic scales, as well as in the identification of elements related with its evolution to early determine the life-threatening lesions and require immediate surgical control or radiological intervention. Multislice computed tomography and other imaging studies allow obtaining images of body structures by planes and provide very detailed and useful information for the diagnosis; nevertheless there is no consensus when it comes to indicating one or the other in trauma. Objective: To develop an algorithm for the efficient indication of imaging study in the poly-traumatized patient. Materials and methods: A technological development research was carried out, where the working universe was made up by 43 patients with polytrauma criteria -who needed imaging studies- admitted to the Clinical Surgical University Hospital Faustino Perez, in the period between March 2020 and March 2021. Results: An algorithm was developed for standardizing the indication of imaging studies in trauma. This work considers the safety and protection of the patient, and the care of the life of the computed axial tomography equipment. Conclusions: The developed algorithm enables decision-making regarding the use of imaging resources in the care of poly-traumatized patients.

10.
Indian J Ophthalmol ; 2023 Jun; 71(6): 2466-2468
Article | IMSEAR | ID: sea-225081

ABSTRACT

Purpose: To derive a formula for accurate axial length (AL) assessment using routine ultrasound in silicone oil?filled eyes, where optical biometry is unavailable or not possible. Methods: This was a prospective, consecutive, nonrandomized study of 50 eyes of 50 patients conducted in a tertiary care hospital in North India. AL measurements were taken using both manual A?scan and IOL master, both in silicone oil?filled status and 3 weeks after silicone oil removal. A correction factor of 0.7 was used for AL adjustment in oil?filled eyes. The corrected AL (cAL) was compared with IOL master values in oil?filled eyes. Agreement analysis was carried out using Bland Altman plot. Linear regression analysis was done using uncorrected manual AL to find a new equation. Data was analyzed using Stata 14. A P value <0.05 was taken as significant. Results: The study included 40 males and 10 females, with an age range of 6–83 years (mean 41.9 years). The mean AL of the oil?filled eye as measured by manual A?scan was 31.76 mm ± 3.09 and by IOL master was 24.7 mm ± 1.74. Linear regression analysis was performed in randomly selected 35 eyes of the observed data to obtain a new equation: predicted AL (PAL) = 14 + 0.3 × manual AL. The mean difference between PAL and optically measured AL with silicone oil in situ was 0.98 ± 1.67. Conclusion: We propose a new formula for better prediction of the correct AL in silicone oil?filled eyes using ultrasound?based AL measurement.

11.
Indian J Ophthalmol ; 2023 May; 71(5): 2115-2131
Article | IMSEAR | ID: sea-225035

ABSTRACT

Purpose: Recently, the proportion of patients with high myopia has shown a continuous growing trend, more toward the younger age groups. This study aimed to predict the changes in spherical equivalent refraction (SER) and axial length (AL) in children using machine learning methods. Methods: This study is a retrospective study. The cooperative ophthalmology hospital of this study collected data on 179 sets of childhood myopia examinations. The data collected included AL and SER from grades 1 to 6. This study used the six machine learning models to predict AL and SER based on the data. Six evaluation indicators were used to evaluate the prediction results of the models. Results: For predicting SER in grade 6, grade 5, grade 4, grade 3, and grade 2, the best results were obtained through the multilayer perceptron (MLP) algorithm, MLP algorithm, orthogonal matching pursuit (OMP) algorithm, OMP algorithm, and OMP algorithm, respectively. The R2 of the five models were 0.8997, 0.7839, 0.7177, 0.5118, and 0.1758, respectively. For predicting AL in grade 6, grade 5, grade 4, grade 3, and grade 2, the best results were obtained through the Extra Tree (ET) algorithm, MLP algorithm, kernel ridge (KR) algorithm, KR algorithm, and MLP algorithm, respectively. The R2 of the five models were 0.7546, 0.5456, 0.8755, 0.9072, and 0.8534, respectively. Conclusion: Therefore, in predicting SER, the OMP model performed better than the other models in most experiments. In predicting AL, the KR and MLP models were better than the other models in most experiments.

12.
Indian J Ophthalmol ; 2023 May; 71(5): 2109-2114
Article | IMSEAR | ID: sea-225034

ABSTRACT

Purpose: To investigate the change in ocular parameters of anisomyopic children treated with 0.01% atropine. Methods: This retrospective study analyzed the data of anisomyopic children who underwent comprehensive examination at a tertiary eye center in India. Anisomyopic subjects (difference of ?1.00 D) of age 6–12 years who were treated with 0.01% atropine or prescribed regular single vision spectacle and had follow?ups of more than 1 year were included. Results: Data from 52 subjects were included. No difference was observed in the mean rate of change of spherical equivalent (SE) of more myopic eyes between 0.01% atropine (?0.56 D; 95% confidence interval [CI]: ?0.82, ?0.30) and single vision lens wearers (?0.59 D; 95% CI: ?0.80, ?0.37; P = 0.88). Similarly, insignificant change in the mean SE of less myopic eyes was noted between the groups (0.01% atropine group, ?0.62 D; 95% CI: ?0.88, ?0.36 vs. single vision spectacle wearer group, ?0.76 D; 95% CI: ?1.00, ?0.52; P = 0.43). None of the ocular biometric parameters showed any difference between the two groups. Though anisomyopic cohort treated with 0.01% atropine revealed a significant correlation between the rate of change of mean SE and axial length in both eyes (more myopic eyes, r = ?0.58; P = 0.001 and less myopic eyes, r = ?0.82; P < 0.001) compared to single vision spectacle wearer group, the change was not significant. Conclusion: Administration of 0.01% atropine had minimal effect on reducing the rate of myopia progression in anisomyopic eyes.

13.
Indian J Ophthalmol ; 2023 May; 71(5): 1941-1947
Article | IMSEAR | ID: sea-225006

ABSTRACT

Purpose: To evaluate the refractive status and ocular biometric parameters in primary angle?closure glaucoma (PACG) eyes with different axial lengths (ALs). Methods: In total, 742 Chinese PACG subjects with complete ophthalmic examinations were enrolled. The refractive status was categorized as myopia (spherical equivalent [SE] ??0.5 D), emmetropia (?0.5 D < SE < +0.5 D), and hyperopia (SE ?+0.5 D), whereas the AL was divided into short (AL <22.5 mm), regular (22.5 ? AL <23.5 mm), and long (AL ?23.5 mm). The refractive status and ocular biometric parameters were compared among different AL groups. Results: The mean AL of the PACG eyes was 22.53 ± 0.84 mm (range: 19.68–25.57 mm). The refractive status was significantly different among different AL groups (P < 0.001). Also, 92.6% of hyperopic PACG eyes showed AL <23.5 mm, and 19.0% of myopic PACG eyes showed AL ?23.5 mm. The SE showed significant differences among different AL groups only in the hyperopic subjects (P = 0.012). The AL was significantly longer in myopic eyes (P < 0.001). The PACG eyes with longer AL exhibited lower keratometry, longer central anterior chamber depth and corneal diameter, and lens position and relative lens position closer to the anterior (P < 0.001). Conclusion: Axial hyperopia was common in PACG eyes, and axial myopia was not uncommon. Relatively anterior lens position could explain the occurrence of PACG in the eyes with long AL.

14.
Article | IMSEAR | ID: sea-220686

ABSTRACT

Background: Meningiomas are tumours originating from meningothelial cells. They are commonly located at intracranial, intraspinal or occasionally ectopic site. They show histological diversity and are categorized into three grades by WHO 2007 Classi?cation. This grading helps in predicting their behaviour and deciding treatment strategy. To study the frequency, clinical details, histological typing and grading of 50 cases of Aims and Objective: meningiomas. To evaluate diagnostic accuracy of radio-imaging and there correlation with histopathological diagnosis is made Total 50 cases of histopathologically con?rmed cases of meningiomas were studied with above mentioned Methods: aims and objectives. Analysis of histological features, typing and grading of all cases were done. Meningioma are the Result: most common extra-axial tumour. Obvious female predominance was observed. The most common histological subtype was meningothelial followed by ?broblastic. In all cases radiological diagnosis correlated with histopathological diagnosis Conclusion: Meningiomas are slow growing extra-axial tumours majority being intracranial, benign grade I followed by grade II and rarely grade III neoplasms occurring most commonly in elderly females

15.
Article | IMSEAR | ID: sea-217875

ABSTRACT

Background: Myopia is a common condition affecting a significant proportion of the pediatric population in Asian countries. Aim and Objectives: This study was undertaken to investigate the associations of optical coherence tomography measurements of macular volume and macular thickness with refractive error and axial length in Indian children. Materials and Methods: The prospective observational study was carried out at MRA Medical College, Ambedkar Nagar, Uttar Pradesh. We enrolled 300 consecutive cases (190 cases and 110 controls) of pediatric age group (6–18 years) between January 2015 and December 2018. Pearson’s correlation was performed with refractive errors, axial length, macular thickness, and volume. Results: Children with myopia (SE ?0.5–?4.57 D) tended to have smaller total macular volume and thinner macular thickness as, compared to control. The correlation of macular thickness and macular volume was analyzed with spherical equivalent (SE) and axial length. Macular thickness had negative correlation with SE and positive with axial length, correlation coefficients being observed as (r = ?0.886 and 0.880, P ? 0.001). Total macular volume correlated negatively with SE, (r= ?0.771, P ?0.001) and positively with axial length (r = 0.764, P ?0.001). Conclusion: Increasing axial myopia was associated with increased macular volume and thickness. It establishes the importance of the fact that refractive error should be considered in the interpretation of macular thickness.

16.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535139

ABSTRACT

Introducción: La equinococosis esplénica es una enfermedad zoonótica adquirida de forma accidental por el humano como huésped intermediario. Reporte de caso: paciente mujer de 26 años de edad, con dolor abdominal localizado en hipocondrio izquierdo, moderada intensidad, calmaba con antiespasmódicos endovenosos; antecedente de dolor abdominal de larga data y procedente de región de Huancavelica, Perú hace 6 años. En examen clínico del abdomen: ruidos hidroaéreos; presentes, simétrico, blando, depresible, doloroso a la palpación en hipocondrio izquierdo, impresiona esplenomegalia, timpanismo conservado; en ecografía menciona quiste hidatídico a nivel del bazo Gharbi IV; en tomografía abdominopélvica con contraste muestra bazo con lesión quística heterogénea, de pared parcialmente calcificada y áreas de densidad grasa que se extiende hasta ligamento gastroesplénico, con diámetro de 73 mm x 54 mm; concluyendo equinococosis extrahepática (equinococosis esplénica), realizándose esplenectomía total. Conclusión: enfermedad rara, incluso en áreas endémicas, que plantea desafíos para su diagnóstico y tratamiento.


SUMMARY Introduction: Splenic echinococcosis is a zoonotic disease accidentally acquired by humans as an intermediate host. Case report: a 26-year-old female patient with abdominal pain located in the left hypochondrium, moderate intensity, calmed with intravenous antispasmodics; a history of long-standing abdominal pain and from the Huancavelica region, Peru, 6 years ago. On clinical examination of the abdomen: hydro-air sounds; present, symmetrical, soft, depressible, painful on palpation in the left hypochondrium, impression of splenomegaly, preserved tympany; the ultrasound mentions a hydatid cyst at the level of the spleen Gharbi IV; Contrast-enhanced abdominal and pelvic tomography shows a spleen with a heterogeneous cystic lesion, with a partially calcified wall and areas of fatty density that extend to the gastrosplenic ligament, with a diameter of 73 mm x 54 mm; concluding extrahepatic echinococcosis (splenic echinococcosis), performing total splenectomy. Conclusion: rare disease, even in endemic areas, which poses challenges for its diagnosis and treatment.

17.
Chinese Journal of Experimental Ophthalmology ; (12): 776-781, 2023.
Article in Chinese | WPRIM | ID: wpr-990912

ABSTRACT

Objective:To investigate the effect of peripheral plus ring size and its potential associations with pupil diameter (PD) on axial length (AL) elongation in myopic patients after wearing orthokeratology lenses.Methods:A case-control study was conducted.One hundred eyes from 100 myopic patients who underwent orthokeratolokgy lenses fitting were enrolled at Beijing Ming Vision and Ophthalmology from January to June 2020.AL and central corneal thickness (CCT) measurements were obtained using Lenstar LS900 ocular biometry, and steep keratometry (Ks), flat keratometry (Kf) were assessed using the TMS-4 corneal topographer.The patients were divided into larger peripheral plus ring diameter (LPPRD) group consisting of 55 eyes with PD<PPRD-0.9 mm and smaller PPRD (SPPRD) group consisting of 45 eyes with PPRD-0.9 mm <PD<PPRD+ 0.9 mm based on PPRD and PD sizes in the tangential difference map.Differences in the above parameters before and after wearing orthokeratology lenses were compared between the two groups.The study followed the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Ineye Hospital of Chengdu University of Traditional Chinese Medicine (No.2021yh-008). All the subjects and their guardians understood the purpose and method of the study and signed the informed consent voluntarily.Results:The PPRD of LPPRD group was (5.15±0.37)mm 12 months after wearing orthokeratology lenses, which was significantly higher than (4.75±0.32)mm of SPPRD group ( t=0.214, P<0.01). The elongation of AL at 3, 6, 9 and 12 months after wearing orthokeratology lenses were (0.13±0.07), (0.23±0.11), (0.31±0.13) and (0.36±0.41)mm in LPPRD group, and (0.06±0.05), (0.11±0.06), (0.14±0.07) and (0.17±0.08)mm in SPPRD group, respectively.There were significant differences in AL elongation at different time points after wearing orthokeratology lenses between the two groups ( Fgroup=30.527, P<0.01; Ftime=16.528, P<0.01), and the AL elongation at different time points was smaller in SPPRD group than in LPPRD group, showing statistically significant differences (all at P<0.01). Compared to before wearing orthokeratology lenses, Ks and Kf were significantly smaller and CCT was thinner 3, 6, 9, and 12 months after wearing orthokeratology lenses in both groups (all at P<0.01). There was no significant difference in Ks, Kf, and CCT between the two groups (all at P>0.05). There was no significant difference in PD at different time points before and after wearing orthokeratology lenses between the two groups ( Fgroup=1.133, P=0.293; Ftime=231.427, P=0.112). Conclusions:The size of peripheral plus ring and its relationship with PD are key factors influencing the AL elongation rate in myopic patients after wearing orthokeratology lenses.With smaller PPRD, patients have slower AL elongation and better myopia control.

18.
Chinese Journal of Experimental Ophthalmology ; (12): 357-365, 2023.
Article in Chinese | WPRIM | ID: wpr-990855

ABSTRACT

Objective:To systematically evaluate the effect of repeated low-level red light (RLRL) therapy on controlling the progression of myopia in children.Methods:Medline, Embase, Cochrane Library, Web of Science, ClinicalTrial.gov and the CNKI, VIP, Wanfang database, and Chinese Clinical Trial Registry (www.chictr.org.cn) were searched from their establishment to September 2022 to obtain the randomized controlled trial (RCT) about RLRL controlling myopia progression in children.Grey literature was also searched.Inclusion and exclusion criteria were developed according to the PICOS principle.Two researchers screened the literature independently, extracted data, and assessed the risk of bias in the included studies using the Cochrane collaboration tool for assessing risk of bias.The data were imported into RevMan 5.4 software for meta-analysis.Mean and standard deviation of data were used to obtain mean differences and 95% confidence intervals of included studies.Changes in spherical equivalent (SE) and axial length (AL) were compared between before and after the intervention in RLRL and single-vision spectacle (experimental group) and single-vision spectacle (control group). The GRADE system was used to grade the quality of evidence for the outcome indicators.Results:A total of 157 studies were obtained.After the screening, 7 RCT studies including 1 038 study subjects met the inclusion criteria.Meta-analysis results showed that retarded SE progression was retarded and AL elongation was reduced significantly after different follow-up durations (1, 3, 6, 12 and 24 months) in experimental group compared with control group.As the follow-up duration extended from 1 month to 24 months, the retard of SE progression increased from 0.14 to 0.93 D, and the reduction of AL increased from 0.07 to 0.48 mm.Both 635 and 650 nm red light significantly retarded SE progression and reduced AL elongation.The two outcome indicators, SE change and AL change were moderate-strength evidence by GRADE.Conclusions:The current moderate-strength evidence shows that RLRL can better retard myopia progression in children than single-vision spectacle glasses.

19.
Chinese Journal of Experimental Ophthalmology ; (12): 140-145, 2023.
Article in Chinese | WPRIM | ID: wpr-990823

ABSTRACT

Objective:To investigate the association of peripheral axial lengths and retinal curvatures with refractive status.Methods:A cross-sectional study was conducted out.Two hundred and eighty-seven eyes of 287 consecutive children aged 6-15 years old who recieved eye examinations at Beijing Tongren Hospital from July to October 2021 were enrolled, including 154 males and 133 females.Uncorrected and best corrected visual acuity were tested with a standard logarithmic visual acuity chart.Spherical equivalent (SE) was measured via an auto refractometer after cycloplegia with tropicamide.The hyperopic, emmetropic and myopic groups were defined with a SE >+ 0.5 D, SE >-0.5 D to ≤+ 0.5 D and SE≤-0.5 D, respectively.Central and 30° peripheral eye lengths (nasal, temporal, superior, inferior) were obtained using the Lenstar LS900.Retinal coordinates were derived from partial coherence interferometry modeling and converted to retinal curvatures.According to the median horizontal peripheral eye length differences (absolute difference between nasal and temporal), participants were assigned to H1 group (absolute difference <0.35 mm) or H2 group (absolute difference ≥0.35 mm). According to the median vertical peripheral eye length differences (absolute difference between superior and inferior), participants were assigned to V1 group (absolute difference <0.32 mm) or V2 group (absolute difference ≥0.32 mm). Four groups of V1H1, V1H2, V2H1 and V2H2 were constructed according to the grouping methods in both directions above.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Beijing Tongren Hospital, Capital Medical University (No.TRECKY2021-162). Written informed consent was obtained from guardians of each subject prior to any medical examination.Results:The central axial length was 23.53(22.93, 24.10)mm.Peripheral eye lengths of temporal, nasal, superior and inferior were 22.75(22.11, 23.22)mm, 22.99(22.32, 23.45)mm, 23.24(22.58, 23.75)mm and 23.12(22.52, 23.56)mm, respectively.Temporal eye length was shorter than nasal, showing a statistically significant difference ( Z=-3.58, P<0.01). Compared with H2 group, H1 group had shorter central, nasal, superior and inferior eye lengths, showing statistically significant differences (all at P<0.05). Compared with V2 group, V1 group had shorter central, nasal and superior eye lengths, showing statistically significant differences (all at P<0.05). SE of H1 group was + 0.06 (-1.06, + 0.75) D, which was significantly greater than -0.32 (-1.64, + 0.56) D of H2 group ( Z=-2.10, P=0.04). SE of V1 group was + 0.13 (-0.81, + 0.80) D, which was significantly greater than -0.56 (-1.83, + 0.48) D of H2 group ( Z=-3.39, P<0.01). The myopia ratio of V1 group was 33.5% (58/173), which was significantly lower than 50.5% (53/105) of V2 group ( χ2=7.83, P<0.01). There was a significant overall difference in SE among VIH1, V1H2, V2H1 and V2H2 groups ( H=24.79, P<0.01). SE was greater in V1H1 group than V1H2, V2H1 and V2H2 groups (all at P<0.01). There was a significant difference in both horizontal and vertical retinal curvatures among different refractive groups ( H=22.34, 19.30; both at P<0.01). The retical curvature in both directions of hyperopic and emmetropic groups were significantly larger than those of myopic group (both at P<0.01). Conclusions:Peripheral eye lengths are asymmetric in school-aged children.Higher asymmetry is associated with myopic shifts.Myopic children have a steeper retina than the hyperopic and emmetropic children.

20.
International Eye Science ; (12): 1754-1759, 2023.
Article in Chinese | WPRIM | ID: wpr-987904

ABSTRACT

AIM: To assess the differences in corneal biomechanical parameters and their correlation with other ocular biometric parameters in myopic patients using a corneal visualisation scheimpflug technology(Corvis ST).METHODS: A total of 132 myopic patients who received treatment in the department of refractive surgery of Eyegood Ophthalmic Hospital from May to December 2021 were selected, and the data of right eye were taken. The subjects were classified into low and moderate myopia(-0.50 to -6.00D), high myopia(&#x003E;-6.00D to &#x003C;-8.00D), and super high myopia(≥-8.00D)according to the spherical equivalent(SE). The basic parameters of corneal biomechanical deformation measured with Corvis ST included the amount of corneal displacement at highest degree of concavity(DA), radius of curvature at highest concavity(HCR), and distance between the two peaks of the cornea at highest concavity(PD); stiffness parameters at applanation 1(SP-A1), integrated radius(IR), deformation amplitude ratio(DA ratio), Ambrosio relational thickness horizontal(ARTh), Corvis biomechanical index(CBI). Other ocular biometric parameters measured included SE, intraocular pressure(IOP), axial length(AL), central corneal thickness(CCT), white-to-white(WTW)and retinal nerve fiber layer(RNFL)thickness. The differences in corneal biomechanical parameters were compared among the three groups of myopic patients, and the correlation between corneal biomechanical parameters and other ocular biometric parameters and age was further analyzed.RESULTS: The SP-A1 in the low and moderate, high, and super high myopia groups were 106.8±16.2, 115.6±21.9, and 106.9±11.5, respectively. The SP-A1 in the high myopia group was higher than that in the low and moderate and severe myopia groups(all P&#x003C;0.05). All corneal biomechanics were significantly correlated with CCT(P&#x003C;0.01); all corneal biomechanics were correlated with IOP except ARTh(P&#x003C;0.05); AL was significantly and positively correlated with PD(r=0.270, P=0.002), weakly and positively correlated with HCR(r=0.177, P=0.043), and weakly and negatively correlated with IR(r=-0.183, P=0.036); WTW was positively correlated with PD, DA and DA ratio(r=0.363, P&#x003C;0.001; r=0.252, P=0.003; r=0.200, P=0.02); there was no correlation between corneal biomechanical parameters and age, SE, and RNFL.CONCLUSION: Corneal stiffness was higher in high myopia patients than in patients with low to moderate and super high myopia. IOP and CCT were both important factors affecting corneal biomechanics. Some of the biomechanical parameters also have certain correlation with AL and WTW. As the growth of axial length, the PD of corneal deformation and HCR were larger, and IR was smaller, but HCR and IR had little significance; the longer the WTW, the greater the corneal deformation amplitude. In clinical practice, attention should be paid to the corneal biomechanical parameters in patients with super high myopia.

SELECTION OF CITATIONS
SEARCH DETAIL